List of iSCSI related hotfixes post SP2 for Windows Server 2008 SP2 Applies to: Windows Server 2008 SP2 Windows Server 2008 Service Pack 2
Note: You should check http://support.microsoft.com for the latest version of the different files. Note 2: These are not available in Windows Update. Note 3: You can download them without entering your e-mail address and captcha if you are a Microsoft Premier customer and have a http://Premier.Microsoft.com account. Note 4: Carefully review the list and decide which might be applicable to your unique environment. Note 5: Test in your test and your quality assurance environment.
Originally published Jan. 2015. Updated Jan. 2015.
List of iSCSI related hotfixes post SP2 for Windows Server 2008 SP2 as of Jan. 2015:
2789430 Isnscli.exe incorrectly displays IPv6 address information that is from a Windows Server 2008 and Windows Server 2008 R2-based iSNS server http://support.microsoft.com/kb/2789430
Update(s): Isns.mof Isnscli.exe 6.0.6002.23004 Isnsdll.dll 6.0.6002.23004 Isnssrv.dll 6.0.6002.23004 Isnsui.exe 6.0.6002.23004 Isnsuid.dll 6.0.6002.23004 Isnswmi.dll 6.0.6002.23004
2780444 "0x0000012E" Stop error occurs when an application sends a 12-byte SCSI opcode to an iSCSI target in Windows Vista SP2, Windows Server 2008 SP2, Windows 7 SP1, and Windows Server 2008 R2 SP1 http://support.microsoft.com/kb/2780444
Update(s): Storport.sys 6.0.6002.22969 Supersede(s): 968675 The storport.sys driver leaks nonpaged pool memory when volumes are scanned, mounted, or dismounted in Windows Server 2008 and Windows Vista http://support.microsoft.com/kb/968675
2727330 Default gateway is set to 0.0.0.0 if you start a Windows Vista-based, Windows 7-based, Windows Server 2008-based or Windows Server 2008 R2-based computer from an iSCSI boot device http://support.microsoft.com/kb/2727330
Update(s): Tcpipreg.sys 6.0.6002.22989 Tcpip.sys 6.0.6002.22989
2710558 Network adapter teaming breaks after you install the hotfix that is described in KB article 2487376 or 2495300 in Windows Vista SP2 or in Windows Server 2008 SP2 http://support.microsoft.com/kb/2710558
Update(s): Agp440.sys 6.0.6002.22848 Isapnp.sys 6.0.6002.22848 Msisadrv.sys 6.0.6002.22848 Mssmbios.sys 6.0.6002.22848 Nv_agp.sys 6.0.6002.22848 Pci.sys 6.0.6002.22848 Rdpdr.sys 6.0.6002.22848 Streamci.dll 6.0.6002.22848 Swenum.sys 6.0.6002.22848 Termdd.sys 6.0.6002.22848 Uliagpkx.sys 6.0.6002.22848 Volmgr.sys 6.0.6002.22848 Volmgrx.sys 6.0.6002.22848 Note: This is related to 2487376 FIX: Stop error when you replace an iSCSI network adapter or a motherboard by using an identical device on a Windows Server 2008-based or Windows Vista-based computer: "0x0000007B"
2697479 Memory leak in Wmiapsrv.exe on a computer that is running Windows Server 2008, Windows Server 2008 R2, Windows Vista or Windows 7 http://support.microsoft.com/kb/2697479
Update(s): Wmiprov.dll 6.0.6002.22971
2695321 IPsec session takes 5 to 6 minutes to connect to a storage controller on a computer that is running Windows Vista, Windows Server 2008, Windows 7, or Windows Server 2008 R2 http://support.microsoft.com/kb/2695321
Update(s): Bfe.dll 6.0.6002.22887 Fwpkclnt.sys 6.0.6002.22887 Fwpuclnt.dll 6.0.6002.22887 Ikeext.dll 6.0.6002.22887 Wfp.mof Wfp.tmf Fwpuclnt.dll 6.0.6002.22887 Wfp.mof
2684681 Iscsicpl.exe process stops responding when you try to reconnect a storage device to a computer that is running Windows Vista, Windows Server 2008, Windows 7, or Windows Server 2008 R2 http://support.microsoft.com/kb/2684681
Update(s): Iscsilog.dll 6.0.6002.22814 Msiscsi.sys 6.0.6002.22814 Supersede(s): 2028982 "0x0000000A" Stop error message in Windows Vista or in Windows Server 2008 if iSCSI storage is installed http://support.microsoft.com/kb/2028982 981357 The handle count of the system process keeps increasing in Windows Server 2008, in Windows Vista, in Windows 7 or in Windows Server 2008 R2 http://support.microsoft.com/kb/981357 979551 "0x0000000A" error message when you use CHAP authentication to start a computer that is running Windows Vista or Windows Server 2008 from an iSCSI device http://support.microsoft.com/kb/979551 975773 Error message when you start a computer that is running Windows Vista or Windows Server 2008 from iSCSI by using CHAP authentication: "Stop 0x0000000A" http://support.microsoft.com/kb/975773 974201 Stop error message when you retrieve WMI connection statistics for iSCSI after you change the iSCSI configurations on a computer that is running Windows Server 2008 or Windows Vista: "0x00000019 BAD_POOL_HEADER" http://support.microsoft.com/kb/974201 971443 An iSCSI target is not recognized as an installation target when you try to install Windows Server 2008 by using an IPv6 connection http://support.microsoft.com/kb/971443 970658 iSCSI Initiator dialog box displays a reconnecting session status after you disconnect and then reconnect the physical connection to the iSCSI target on a computer that is running Windows Server 2008 or Windows Vista http://support.microsoft.com/kb/970658 970312 A crash dump file is not generated as expected when you use certain iSCSI network adapters on a Windows Server 2008-based computer http://support.microsoft.com/kb/970312
2652137 FIX: Communications fail when you try to use the Windows Server 2008 R2 provider package to communicate with a Windows Server 2012 iSCSI target http://support.microsoft.com/kb/2652137
Update(s): Strgprvdmgmt.mfl Strgprvdmgmt.dll 6.2.9200.16384 Strgprvdmgmt.mof Wtvdsprov.dll 6.2.9200.16384 Wtsnapshotprovider.dll 6.2.9200.16384 Wtvdsprov.dll.mui 6.2.9200.16384 Wtsnapshotprovider.dll.mui 6.2.9200.16384
2487376 FIX: Stop error when you replace an iSCSI network adapter or a motherboard by using an identical device on a Windows Server 2008-based or Windows Vista-based computer: "0x0000007B" http://support.microsoft.com/kb/2487376
Update(s): Agp440.sys 6.0.6002.22567 Isapnp.sys 6.0.6002.22567 Msisadrv.sys 6.0.6002.22567 Mssmbios.sys 6.0.6002.22567 Nv_agp.sys 6.0.6002.22567 Pci.sys 6.0.6002.22567 Rdpdr.sys 6.0.6002.22567 Streamci.dll 6.0.6002.22567 Swenum.sys 6.0.6002.22567 Termdd.sys 6.0.6002.22567 Uliagpkx.sys 6.0.6002.22567 Volmgr.sys 6.0.6002.22567
2487376 A memory leak occurs in the Wmiprvse.exe process when you query an iSCSI WMI class in Windows Vista or in Windows Server 2008 http://support.microsoft.com/kb/2487376
Update(s): Iscsicli.exe 6.0.6002.22229 Iscsidsc.dll 6.0.6002.22229 Iscsied.dll 6.0.6002.22229 Iscsiexe.dll 6.0.6002.22229 Iscsium.dll 6.0.6002.22229 Iscsiwmi.dll 6.0.6002.22229 Supersede(s): 974780 Error message when you log on to an iSCSI target by using the Iscsicpl.exe tool on a computer that is running an Itanium-based version of Windows Server 2008 if CHAP authentication is enabled: "Invalid access to memory location" http://support.microsoft.com/kb/974780
967999 Stop error message when you start a Windows Server 2008-based computer from an iSCSI boot device that is connected over MPIO paths:"Stop 0x0000007E" http://support.microsoft.com/kb/967999
Update(s): Disk.sys 6.0.6002.22756